INSTALLATION INSTRUCTIONS
Model # 8847/8997
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
1.
Shut off power at the circuit breaker and remove old
fixture including mounting hardware.
2.
Carefully unpack your new fixture and lay out all the
parts i
n a clear area. Take care not to misplace any
small parts necessary for installation.
3.
Pull black and white wires out of electrical outlet box
(A).
4. Thread the two studs (B) into the pre-
drilled holes in
the circular strap (C) spaced the same distance
apart as the holes in the back plate (H),
then tighten
with the nut (E).
5. Attach Circular Strap (C) using Outlet
Box Screws
(F) to the outlet box (A), (Fig 1).
6.
Connect the electrical wires as shown in Fig.2.
M
aking sure that all wire connectors are secured. If
your outlet box
copper), connect the fixture s Ground wire to it.
Otherwise, connect the fixtures Gr
ound wire directly
to the circular strap
using the Green Screw (D)
provided.
7.
To prevent moisture from entering the outlet box (A)
and causing a short, use clear silicone Sealant to
outline the outside of fixture back plate (H) where it
meets the wall leaving a space at bottom to allow
moisture a means to escape.
8. Place the back plate (H) into stud (B) and secure it
tightly against the wall using cap nut (G). (Fig 1)
9. At this point, unscrew the screws (I), remove the
cage (J) with the shade to install the light bulbs in
accordance with the fixture specification DO NOT
EXCEED THE MAXIMUM WATTAGE RATING!
10.
Replace the cage (J) with the shade, secure with the
screws (I).
Your installation is now complete. Return power to the
outlet box and test the fixture.
Fig. 1
BARE COPPER(GROUND)
Fig.2
FIXTURE
WIRES
WHITE
BLACK
(HOT)
WIRES
HOUSE
GREEN OR
WHITE
(NEUTRAL)
WIRES
HOUSE
(GROUND)
COPPER
BARE
FIXTURE
WIRES
BLACK
WIRES
FIXTURE
GREEN OR
HOUSE
WIRES
CAUTION
-
RISK OF FIRE CONSULT A
QUALIFIED ELECTRICIAN TO ENSURE
CORRECT BRANCH CIRCUIT CONDUCTOR
R
B
C
E
A
D