Minka Lavery 4350-593 Instruction Manual

Browse online or download Instruction Manual for Unknown Minka Lavery 4350-593. Minka Lavery 4350-593 Instructions / Assembly User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION INSTRUCTIONS FOR 4350-593
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
ASSEMBLING THE FIXTURE (Fig.2)
1. Shut off the power at the circuit breaker and remove the old
fixture from ceiling, including the old crossbar.
2. Carefully unpack the new fixture and lay all the parts on a clear
surface.
3. Return the arms to suitable position, see figure.2.
4. Attach the loop (I) to the fixture body (K) by turning it
clockwise until tight.
5. Attach the top of the arm (M) to the fixture body (K) with the
ball screw (J) aligning the hole of the top of the arm (M).
HANGING THE FIXTURE (Fig.1)
6. Thread the nipple (C) into the loop (F) until snug.
7. Thread the other end of the nipple (C) with the loop attached into
the crossbar (D) until snug.
8. Place lock washer (B) over end of nipple protruding through
crossbar and thread hex nut (A) onto nipple until tight.
9. Take this crossbar assembly and mount to ceiling junction box
with junction box screws (E) (Size: #8-32*1/2"L). Tighten
screws securely with screwdriver.
10. Using proper chain pliers to open one end link of the chain
provided and connect to the fixture loop (I); then close the link.
11. By measuring, determine correct number of links needed for
proper hanging height. Using proper chain pliers disconnect and
discard remaining chain.
12. Lace the fixture wires through the chain.
13. Slip loop collar (H) and the canopy (G) over the chain.
14. Open the other end link of the chain and hang the fixture on the
loop at the ceiling. Close the link.
15. Feed the fixture wires through the loop (F) and nipple (C) and
pull until tight.
CONNECTING THE WIRES (Fig.3)
16. Connect the electrical wire as shown in figure 3, making sure
that all wire connectors are secured. If your outlet has a ground
wire (green or bare copper), connect the fixtures ground wire to
it. If the junction box has no ground wire, attach the bare copper
fixture wire to the green ground screw (Screw: #8-32*3/8”L) on
the crossbar. Tuck the wire connections neatly into the ceiling
junction box.
COMPLETING THE INSTALLATION (Fig.1 and Fig.2)
17. Raise the canopy (G) all the way to the ceiling; then raise the
loop collar (H) and thread into ceiling loop protruding through
canopy.
18. Place the tube (L) over the socket of the arm (M).
19. Install the light bulbs (not included) in accordance with the
fixture’s specifications: DO NOT EXCEED THE MAXIMUM
WATTAGE RATING! (NE PAS DEPASSER LA
PUISSANCE NOMINALE MAXIMALE!)
20. Hang the crystals (N) to the loop of the arm (M).
21. Hang the crystal (O) to the bottom of the fixture body (K).
Your installation is now complete. Return power to the junction box
and test the fixture.
Fig.2
CHAIN HUNG FIXTURE INSTRUCTION
Notice: It is important to use proper chain pliers (not included) To
OPEN and CLOSE the chain included with this fixture. Do not
open them with other tools that may twist or stress the chain links.
It is important to use proper chain pliers like the ones shown in
the diagram.
Fig.3
Fig.1
CM
USC
lntertek
Page view 0
1

Summary of Contents

Page 1

INSTALLATION INSTRUCTIONS FOR 4350-593 WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER . AVERTISSEMENT! COUPER LE COURANT

Comments to this Manuals

No comments