Minka Lavery 1566-477 Installation Guide Page 1

Browse online or download Installation Guide for Unknown Minka Lavery 1566-477. Minka Lavery 1566-477 Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION INSTRUCTION 1565-477 1566-477
For Flush Mount Ceiling Fixtures
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
Fig.1
Fig.2
MOUNTING THE FIXTURE
1. Shut off the power at the fuse box or circuit breaker box.
Remove the old fixture from ceiling, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts
on a clear area. Take care not to lose any small parts
necessary for installation.
3. Thread the two Mounting Screws (A) about 1/4” into the
pre-drilled holes in the Crossbar (B) spaced the same
distance apart as the holes in the pan (E).
4. Attach the crossbar (B) to the outlet Box using the two
screws (C) from the outlet Box. The side of the crossbar
marked "GND" must face out.
5. Hold the fixture (D) and pan (E) towards the crossbar and
connect the electrical wires as follows (See Fig.2). Connect
the black wire from the fixture to the black house (hot)
wire; connect the white wire from the fixture to the white
house (neutral) wire. Make sure all wire nuts are secured.
You may wrap the connections with electrical tape.
If your
outlet box has a ground wire (green or bare copper) connects
fixture’s ground wire to it. Other wise attach the bare copper
fixture wire to the
green ground screw on the crossbar. Tuck
the wire connections neatly into the ceiling junction box as
you are holding the fixture assembly toward the ceiling.
6. Finish mounting the pan (E) by placing it over both
Mounting screws (A) so that the screws protrude from the
keyholes in the bottom of the pan (E). Rotate the pan (E)
until the screw are seat in the slots of the keyholes and
tighten it with a screwdriver.
7. Install the light bulbs in accordance with the fixture’s
specifications. DO NOT EXCEED THE MAXIMUM
WATTAGE RATING!
8. Thread pipe (G) into center coupling of the pan (E) and
tighten it with nut (F).
9. Put the glass shade (H) onto the fixture (D) and protruding
the pipe (G) from the center hole of the glass shade.
10. Thread lock nut (I) onto pipe (G), then attach the finial
base (J) and tighten firmly with finial (K).
Your installation is now complete. Return power to the
junction box and test the fixture.
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE
Green Screw
MIN 90℃SUPPLY CONDUCTORS
Page view 0
1

Summary of Contents

Page 1 - If your

INSTALLATION INSTRUCTION 1565-477 1566-477 For Flush Mount Ceiling Fixtures WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER . Fig.1 F

Comments to this Manuals

No comments