Minka Lavery 4753-206 Installation Guide

Browse online or download Installation Guide for Unknown Minka Lavery 4753-206. Minka Lavery 4753-206 Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION INSTRUCTIONS FOR 4753-206
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
Fig.1
Fig.2
ASSEMBLING THE FIXTURE (Fig.2)
1. Attach the loop (I) to the fixture body (F) by turning it clockwise
until tight.
2. Place the candle sleeve (E) and the spider ring (D) over the socket of
the fixture body (F), then lock it securely with the check ring
(C) .Install the light bulb (NOTE: DO NOT EXCEED THE
SPECIFIED WATTAGE! Max.3-60w) and put the glass shade (B)
on to the spider ring (D), then put the decorative frame (A) over the
glass shade (B).
3. Attach the small loop (H) of the acrylic ball to the center tube of the
fixture body (F).
4. Attach the crystal (G) to the small ring of the arm as shown.
HANGING THE FIXTURE (Fig.1)
1. Shut off the power at the circuit breaker and remove old fixture from
ceiling, including the old crossbar.
2. Carefully unpack new fixture and lay all the parts on a clear surface.
3. Thread nipple (C) into loop (F) until snug.
4. Thread other end of nipple (C) with loop attached into crossbar (D)
until snug.
5. Place lock washer (B) over end of nipple protruding through crossbar
and thread hex nut (A) onto nipple until tight.
6. Take this crossbar assembly and mount to ceiling junction box with
junction box screws (E). Tighten screws securely with screwdriver.
7. Using proper chain pliers to open one end link of the chain provided
and connect to the fixture loop (J). Close the link.
8. By measuring, determine correct number of links needed for proper
hanging height. Using proper chain pliers disconnect and discard
remaining chain.
9. Lace the fixture wires through the chain.
10. Slip loop collar (H) over the chain, then do the same with the canopy
(G).
11. Open the other end link of the chain and hang the fixture on the loop
at the ceiling. Close the link.
12. Feed the fixture wires through the loop (F) and nipple (C) and pull
until taut.
CONNECTING THE WIRES (Fig.3)
1. Take the black wire from the ceiling junction box and the smooth
wire leg from the fixture and twist bare ends together. Twist wire
connector onto end of wire until snug.
2. Repeat same process with white junction box wire and ribbed wire
leg of fixture wire. NOTE: Twist wires together in the same direction
you twist the wire connector onto wires.
3. If your junction box has a grounding wire (green or bare copper),
attach this wire and the bare copper wire from the fixture together as
step 1.If junction box has no ground wire, attach the bare copper
fixture wire to the green ground screw on the crossbar.
4. Tuck these wire connections neatly into the ceiling outlet box and
then raise the canopy (G) all the way to the ceiling. Raise the loop
(H) and thread onto ceiling loop protruding through canopy
Your installation is now complete. Return power to the junction box
and test the fixture.
CHAIN HUNG FIXTURE INSTRUCTION
Notice: It is important to use proper chain pliers (not
included) To OPEN and CLOSE the chain included with
this fixture. Do not open them with other tools that may
twist or stress the chain links. It is important to use
proper chain pliers like the ones shown in the diagram.
Fig.3
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE
Page view 0